服务器逻辑卷 /dev/vg0/lv1: read failed after 0 of 4096 at 0: Input/output error
前提:
因云服务器之前使用1000G冗余过大,调整为200G空间
1.问题描述
NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT vda 252:0 0 40G 0 disk └─vda1 252:1 0 40G 0 part / vdb 252:16 0 1000G 0 disk └─vdb1 252:17 0 950G 0 part └─vg0-lv1 (dm-0) 253:0 0 950G 0 lvm vdc 252:32 0 200G 0 disk └─vdc1 252:33 0 196G 0 part └─data_vg-data_lv (dm-0) 253:0 0 196G 0 lvm /home
卸载/dev/vdb1后pvs原先/dev/vg0/lv1错误
[root@ ~]# pvs /dev/vg0/lv1: read failed after 0 of 4096 at 0: Input/output error /dev/vg0/lv1: read failed after 0 of 4096 at 1020050472960: Input/output error /dev/vg0/lv1: read failed after 0 of 4096 at 1020050530304: Input/output error /dev/vg0/lv1: read failed after 0 of 4096 at 4096: Input/output error PV VG Fmt Attr PSize PFree /dev/vdc1 data_vg lvm2 a--u 196.00g 0
2.查看设备
[root@ ~]# dmsetup status data_vg-data_lv: 0 411033600 linear vg0-lv1: 0 1992286208 linear
3.移除设备
dmsetup remove --force /dev/vg0/lv1