M10 更换主板

M10 更换主板

欢迎来到 来到大浪涛天的博客

M10更换主板

1. 移除前准备工作

1.1 系统检查

XSCF> showlogs error
XSCF> showhardconf
XSCF> version -c xcp
XSCF> showpparstatus -a
XSCF> showdomainstatus -p 0
XSCF> poweroff -a

2. 移除系统板

2.1 移除所有的线缆
2.2 推出机器
2.3 打开风扇盖子
2.4 移除盖板
2.5 移除风扇槽和电源背板
enter description here
2.6 移除所有风扇模块
2.7 移除所有内存
2.8 移除所有连接在主板上的线缆

  • a Three (3) cables on the motherboard unit that connect the PSU backplane to the motherboard unit
  • b One (1) cable that connects the PSU backplane to the HDD backplane The cable does not have to be removed from the HDD backplane.
  • c Two (2) cables that connect the HDD backplane to the motherboard unit
  • d Two (2) cables that connect the operation panel to the motherboard unit
    主板线缆
    2.9 解锁主板的五颗螺丝
    五颗螺丝
    2.10 移出主板
    移除主板

3 移除Switching the microSD Card

移除sd卡.pngenter description here
enter description here
enter description here

4. 安装主板

XSCF> version -c xcp -v
October 20, 2013 16:59:00
XSCF> setdate -s 102016592013.00
 XSCF> setpparparam -p 0 -s bootscript "setenv auto-boot false"
 Start the system.
 Enable the RAID volume to check the status.
 Close the rack door.
 ok select /pci@8000/pci@4/pci@0/pci@0/scsi@0 
 {0} ok show-volumes
 {0} ok 0 activate-volume 
 Volume 0 is now activated 
 {0} ok show-volumes
 {0} ok unselect-dev
 {0} ok select /pci@8000/pci@4/pci@0/pci@0/scsi@0 {0} ok show-volumes
Volume 0 Target 11e Type RAID1 (Mirroring)
Name raid1-volume WWID 0c233a838262c6c5 Optimal Enabled Data Scrub In Progress
 Specify the RAID volume that was confirmed in step 1 as the boot device. Follow the rules below when specifying the RAID volume.
a. Replace the number "0" at the beginning of WWID of the RAID volume with "3".
Since the WWID of the RAID volume that was confirmed in Step 1 is "0c233a838262c6c5," it becomes "3c233a838262c6c5."
b. To the WWID of the RAID volume, the one in which you replaced a digit, add "disk@w" to the beginning of it, and append ",0:a" to its end.
In this case, we obtain "disk@w3c233a838262c6c5,0:a".
c. Specify the RAID volume of b. with its device path name from the top. When specifying it, add the device path selected in Step 1 "/pci@8000/pci@4/ pci@0/pci@0/scsi@0/" to the beginning of "disk@w3c233a838262c6c5,0:a".
 {0} ok setenv boot-device /pci@8000/pci@4/pci@0/pci@0/scsi@0/disk@ w3c233a838262c6c5,0:a

posted @ 2020-04-30 01:30  OuYangTao  阅读(292)  评论(0编辑  收藏  举报