ERC检查语法
提示:很多名次是要定义的,需要结合layout的情况,进行定义。
一、高压和低压直接相连的情况
ATH CHECKING
{@……
THICK_NSD = (NSD AND HGO) NOT ESD
THICK_PSD = (PSD AND HGO) NOT ESD
THIN_F_POLY = ((POLY NOT INTERACT RPOLY_ALL) NOT HGO) NOT ESD
NET AREA RATID THIN_F_POLY THICK_NSD > 0
NET AREA RATID THIN_F_POLY THICK_PSD > 0 //net area ratid 这个是相交面积的固定语法
}
二、电源和地是否连接错了
// well and sub bias check //
{@PTAP CONNECTS TO POER
NET PTAP LVS_POWER_NAME //NET A B
}
三、浮空的栅极
// floating gate
{@……
A = (POLY INTERACT GATE_ALL) NOT INTERACT (CONT AND M1)
B = ((GATE_ALL INTERACT A) OR (POLY INTERACT (GATE_ALL INTERACT A))) INTERACT (CONT AND M1)
A NOT B
}
四、浮空的阱
// Floating well
{@ there is no power or ground node information connecting to well or sub
A1 = NET NDTE LVS_POWER_NAME
NDTE NOT A1
B1 = NET NWE LVS_POWER_NAME
NWE NOT B1
C1......
}
五、浮空的有源区
// floating diff
{@floating diffsion no any cont
NTAP NOT INTERACT (CONTA AND M1)
PTAP NOT INTERACT (CONT AND M1)
}
六、浮空的孔
// floating contact
{@……
CONT NOT INTERACT (DIFF OR POLY)
}
七、浮空的金属
// floatingmetal
{@……
M2 NOT INTERACT VIA1//这里是TM2的情况,如果是TM3、TM3以此类推。
M1 NOT INTERACT (VIA1 OR CONT)
}

浙公网安备 33010602011771号