VB中实现IObjectSafety接口以声明控件安全的方法

 

      VB编写的ActiveX控件,在被Javascript脚本调用时会弹出讨厌的对话框,警告用户即将运行不安全的ActiveX脚本,因此必须要实现IObjectSafety接口以声明控件是脚本安全的,下面是具体方法:

      1. 新建一个目录作为你的工程目录;

      2. 插入VB的安装盘,进入%安装盘根目录%\COMMON\TOOLS\VB\UNSUPPRT\TYPLIB,将里面的4个文件C1.EXE、CL.EXE、MKTYPLIB.EXE、MSPDB41.DLL拷贝到刚才的工程目录中;

      3. 打开记事本,粘贴下面的代码然后另存为objsafe.odl,保存在工程目录中;

       [
          uuid(C67830E0-D11D-11cf-BD80-00AA00575603),
          helpstring("VB IObjectSafety Interface"),
          version(1.0)
      ]
      library IObjectSafetyTLB
      {
          importlib("stdole2.tlb");
          [
              uuid(CB5BDC81-93C1-11cf-8F20-00805F2CD064),
              helpstring("IObjectSafety Interface"),
              odl
          ]
          interface IObjectSafety:IUnknown {
              [helpstring("GetInterfaceSafetyOptions")]
              HRESULT GetInterfaceSafetyOptions(
                        [in]  long  riid,
                        [in]  long *pdwSupportedOptions,
                        [in]  long *pdwEnabledOptions);

              [helpstring("SetInterfaceSafetyOptions")]
              HRESULT SetInterfaceSafetyOptions(
                        [in]  long  riid,
                        [in]  long  dwOptionsSetMask,
                        [in]  long  dwEnabledOptions);
           }
       }

      4. 运行cmd进入命令行,利用CD命令进入工程目录,然后输入以下命令并回车:

            MKTYPLIB objsafe.odl /tlb objsafe.tlb

      5. 进入Visual Basic,新建ActiveX空间工程。在属性菜单里,将工程名修改为IObjSafety,控件名修改为DemoCtl。给空间中添加一个按钮,并在这个按钮的点击事件里加入一句:MsgBox "Test";

      6. 在"工程"菜单里点击"引用",接着点浏览,然后选择加入Objsafe.tlb;

      7. 给你的工程添加一个模块,模块的代码如下,模块名称为basSafeCtl;

       Option Explicit

      Public Const IID_IDispatch = "{00020400-0000-0000-C000-000000000046}"
      Public Const IID_IPersistStorage = _
        "{0000010A-0000-0000-C000-000000000046}"
      Public Const IID_IPersistStream = _
        "{00000109-0000-0000-C000-000000000046}"
      Public Const IID_IPersistPropertyBag = _
        "{37D84F60-42CB-11CE-8135-00AA004BB851}"

      Public Const INTERFACESAFE_FOR_UNTRUSTED_CALLER = &H1
      Public Const INTERFACESAFE_FOR_UNTRUSTED_DATA = &H2
      Public Const E_NOINTERFACE = &H80004002
      Public Const E_FAIL = &H80004005
      Public Const MAX_GUIDLEN = 40

      Public Declare Sub CopyMemory Lib "kernel32" Alias "RtlMoveMemory" _
         (pDest As Any, pSource As Any, ByVal ByteLen As Long)
      Public Declare Function StringFromGUID2 Lib "ole32.dll" (rguid As _
         Any, ByVal lpstrClsId As Long, ByVal cbMax As Integer) As Long

      Public Type udtGUID
          Data1 As Long
          Data2 As Integer
          Data3 As Integer
          Data4(7) As Byte
      End Type

      Public m_fSafeForScripting As Boolean
      Public m_fSafeForInitializing As Boolean

      Sub Main()
          m_fSafeForScripting = True
          m_fSafeForInitializing = True
      End Sub

      8. 修改工程属性,将启动项改为Sub_Main;

      9. 在你自己的控件中,在Option Explicit后加入一行:Implements IObjectSafety;

      10. 给你的控件中加入下面的代码:

       Private Sub IObjectSafety_GetInterfaceSafetyOptions(ByVal riid As _
      Long, pdwSupportedOptions As Long, pdwEnabledOptions As Long)

          Dim Rc      As Long
          Dim rClsId  As udtGUID
          Dim IID     As String
          Dim bIID()  As Byte

          pdwSupportedOptions = INTERFACESAFE_FOR_UNTRUSTED_CALLER Or _
                                INTERFACESAFE_FOR_UNTRUSTED_DATA

          If (riid <> 0) Then
              CopyMemory rClsId, ByVal riid, Len(rClsId)

              bIID = String$(MAX_GUIDLEN, 0)
              Rc = StringFromGUID2(rClsId, VarPtr(bIID(0)), MAX_GUIDLEN)
              Rc = InStr(1, bIID, vbNullChar) - 1
              IID = Left$(UCase(bIID), Rc)

              Select Case IID
                  Case IID_IDispatch
                      pdwEnabledOptions = IIf(m_fSafeForScripting, _
                    INTERFACESAFE_FOR_UNTRUSTED_CALLER, 0)
                      Exit Sub
                  Case IID_IPersistStorage, IID_IPersistStream, _
                     IID_IPersistPropertyBag
                      pdwEnabledOptions = IIf(m_fSafeForInitializing, _
                    INTERFACESAFE_FOR_UNTRUSTED_DATA, 0)
                      Exit Sub
                  Case Else
                      Err.Raise E_NOINTERFACE
                      Exit Sub
              End Select
          End If
      End Sub

      Private Sub IObjectSafety_SetInterfaceSafetyOptions(ByVal riid As _
      Long, ByVal dwOptionsSetMask As Long, ByVal dwEnabledOptions As Long)
          Dim Rc          As Long
          Dim rClsId      As udtGUID
          Dim IID         As String
          Dim bIID()      As Byte

          If (riid <> 0) Then
              CopyMemory rClsId, ByVal riid, Len(rClsId)

              bIID = String$(MAX_GUIDLEN, 0)
              Rc = StringFromGUID2(rClsId, VarPtr(bIID(0)), MAX_GUIDLEN)
              Rc = InStr(1, bIID, vbNullChar) - 1
              IID = Left$(UCase(bIID), Rc)

              Select Case IID
                  Case IID_IDispatch
                      If ((dwEnabledOptions And dwOptionsSetMask) <> _
                   INTERFACESAFE_FOR_UNTRUSTED_CALLER) Then
                          Err.Raise E_FAIL
                          Exit Sub
                      Else
                          If Not m_fSafeForScripting Then
                              Err.Raise E_FAIL
                          End If
                          Exit Sub
                      End If

                  Case IID_IPersistStorage, IID_IPersistStream, _
                IID_IPersistPropertyBag
                      If ((dwEnabledOptions And dwOptionsSetMask) <> _
                    INTERFACESAFE_FOR_UNTRUSTED_DATA) Then
                          Err.Raise E_FAIL
                          Exit Sub
                      Else
                          If Not m_fSafeForInitializing Then
                              Err.Raise E_FAIL
                          End If
                          Exit Sub
                      End If

                  Case Else
                      Err.Raise E_NOINTERFACE
                      Exit Sub
              End Select
          End If
      End Sub

      11. 在"文件"菜单中点击"生成ocx文件",ok,现在你的控件已经是脚本安全的了,可以直接使用js脚本进行调用了。

 

posted @ 2009-06-24 16:53  京桥刹那  阅读(996)  评论(0编辑  收藏  举报