COSMO一代星(CSK)二代星(CSG)重采样、配准
- 导入
par_CS_SLC # CSK 导入
par_CSG_SLC # CSG 导入
- 裁剪(转格式)
# CSG 是 FCOMPLEX,CSK 是 SCOMPLEX
SLC_copy ./original_data/20220723_HH_006.slc ./original_data/20220723_HH_006.slc.par ./SLC_dir/20220723_HH.slc ./SLC_dir/20220723_HH.slc.par 2 # CSG 转格式为 SCOMPLEX
- 重采样
# 两者采样分辨率不同
# CSK:
# range_pixel_spacing: 1.1420665m azimuth_pixel_spacing: 1.9224644m
# CSG:
# range_pixel_spacing: 1.0706822m azimuth_pixel_spacing: 1.9180873m
# CSG 采样频率高,转 CSK 需要小于 1 的采样因子:
# 1.0706822 / 1.1420665 = 0.93749549610289768590533038137446
# 1.9180873 / 1.9224644 = 0.99772318280640203272424706538129
# 重采样后的行列数:
# 20808 * 0.93749549610289768590533038137446 = 19507
# 24957 * 0.99772318280640203272424706538129 = 24900
resamp_image ./SLC_dir/20220723_HH.slc 20808 0.93749549610289768590533038137446 0.99772318280640203272424706538129 ./SLC_dir/20220723_resamp.slc 19507 24900 6 6
# 重采样不产生 .par 参数文件。
# 复制 20220723_HH.slc.par 一份,重命名为 20220723_resamp.slc.par。
# 修改参数文件中的采样分辨率和行列数
# range_samples: 19507
# azimuth_lines: 24900
# range_samples: 19507
# azimuth_lines: 24900
- 配准
mk_tab ./SLC_dir slc par SLC_tab
mk_mli_all SLC_tab ./MLI_dir 1 1 # 多视
SLC_resamp_all SLC_tab ./SLC_dir/20230728_HH.slc ./SLC_dir/20230728_HH.slc.par ./RSLC_dir RSLC_tab 0
SLC_resamp_all SLC_tab ./SLC_dir/20230728_HH.slc ./SLC_dir/20230728_HH.slc.par ./RSLC_dir RSLC_tab 1
SLC_resamp_all SLC_tab ./SLC_dir/20230728_HH.slc ./SLC_dir/20230728_HH.slc.par ./RSLC_dir RSLC_tab 2
SLC_resamp_all SLC_tab ./SLC_dir/20230728_HH.slc ./SLC_dir/20230728_HH.slc.par ./RSLC_dir RSLC_tab 3
SLC_resamp_all SLC_tab ./SLC_dir/20230728_HH.slc ./SLC_dir/20230728_HH.slc.par ./RSLC_dir RSLC_tab 4
# final model fit std. dev. (samples) range: 0.0446 azimuth: 0.0911
*有说不用重采样,直接用‘SLC_coreg.py’配准也可以。还没尝试。