VS2008,System.Runtime.InteropServices.COMException (0x800401F3): Invalid class string (Exception from HRESULT: 0x800401F3 (CO_E_CLASSSTRING))

在VS2008环境中编译调试运行不报错,但在发布的exe文件运行就报错

System.Runtime.InteropServices.COMException (0x800401F3): Invalid class string (Exception from HRESULT: 0x800401F3 (CO_E_CLASSSTRING)),不得其解。

See the end of this message for details on invoking

just-in-time (JIT) debugging instead of this dialog box.

 

************** Exception Text **************

System.Runtime.InteropServices.COMException (0x800401F3): Invalid class string (Exception from HRESULT: 0x800401F3 (CO_E_CLASSSTRING))

   at OPCAutomation.OPCServerClass.Connect(String ProgID, Object Node)

   at PlantAdminForPierburg.MainForm.ConnectToOPC(String OPCServerName, String OPCServerNode) in C:\Users\user\Desktop\IPCForPIERBURGSUV2018\PlantAdminForPIERBURG\MainForm.vb:line 1908

   at PlantAdminForPierburg.MainForm.MainForm_Load(Object sender, EventArgs e) in C:\Users\user\Desktop\IPCForPIERBURGSUV2018\PlantAdminForPIERBURG\MainForm.vb:line 64

   at System.EventHandler.Invoke(Object sender, EventArgs e)

   at System.Windows.Forms.Form.OnLoad(EventArgs e)

   at System.Windows.Forms.Form.OnCreateControl()

   at System.Windows.Forms.Control.CreateControl(Boolean fIgnoreVisible)

   at System.Windows.Forms.Control.CreateControl()

   at System.Windows.Forms.Control.WmShowWindow(Message& m)

   at System.Windows.Forms.Control.WndProc(Message& m)

   at System.Windows.Forms.ScrollableControl.WndProc(Message& m)

   at System.Windows.Forms.ContainerControl.WndProc(Message& m)

   at System.Windows.Forms.Form.WmShowWindow(Message& m)

   at System.Windows.Forms.Form.WndProc(Message& m)

   at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m)

   at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m)

   at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)

 

 

************** Loaded Assemblies **************

mscorlib

    Assembly Version: 2.0.0.0

    Win32 Version: 2.0.50727.8784 (QFE.050727-8700)

    CodeBase: file:///C:/Windows/Microsoft.NET/Framework/v2.0.50727/mscorlib.dll

----------------------------------------

PlantAdminForPierburg

    Assembly Version: 1.0.0.0

    Win32 Version: 1.0.0.0

    CodeBase: file:///C:/Users/user/Desktop/IPCForPIERBURGSUV2018/PlantAdminForPIERBURG/bin/Release/PlantAdminForPierburg.exe

----------------------------------------

Microsoft.VisualBasic

    Assembly Version: 8.0.0.0

    Win32 Version: 8.0.50727.5483 (Win7SP1GDR.050727-5400)

    CodeBase: file:///C:/Windows/assembly/GAC_MSIL/Microsoft.VisualBasic/8.0.0.0__b03f5f7f11d50a3a/Microsoft.VisualBasic.dll

----------------------------------------

System

    Assembly Version: 2.0.0.0

    Win32 Version: 2.0.50727.8770 (QFE.050727-8700)

    CodeBase: file:///C:/Windows/assembly/GAC_MSIL/System/2.0.0.0__b77a5c561934e089/System.dll

----------------------------------------

System.Windows.Forms

    Assembly Version: 2.0.0.0

    Win32 Version: 2.0.50727.5491 (Win7SP1GDR.050727-5400)

    CodeBase: file:///C:/Windows/assembly/GAC_MSIL/System.Windows.Forms/2.0.0.0__b77a5c561934e089/System.Windows.Forms.dll

----------------------------------------

System.Drawing

    Assembly Version: 2.0.0.0

    Win32 Version: 2.0.50727.5495 (Win7SP1GDR.050727-5400)

    CodeBase: file:///C:/Windows/assembly/GAC_MSIL/System.Drawing/2.0.0.0__b03f5f7f11d50a3a/System.Drawing.dll

----------------------------------------

System.Configuration

    Assembly Version: 2.0.0.0

    Win32 Version: 2.0.50727.5483 (Win7SP1GDR.050727-5400)

    CodeBase: file:///C:/Windows/assembly/GAC_MSIL/System.Configuration/2.0.0.0__b03f5f7f11d50a3a/System.Configuration.dll

----------------------------------------

System.Xml

    Assembly Version: 2.0.0.0

    Win32 Version: 2.0.50727.8773 (QFE.050727-8700)

    CodeBase: file:///C:/Windows/assembly/GAC_MSIL/System.Xml/2.0.0.0__b77a5c561934e089/System.Xml.dll

----------------------------------------

System.Runtime.Remoting

    Assembly Version: 2.0.0.0

    Win32 Version: 2.0.50727.8771 (QFE.050727-8700)

    CodeBase: file:///C:/Windows/assembly/GAC_MSIL/System.Runtime.Remoting/2.0.0.0__b77a5c561934e089/System.Runtime.Remoting.dll

----------------------------------------

System.Data

    Assembly Version: 2.0.0.0

    Win32 Version: 2.0.50727.8762 (QFE.050727-8700)

    CodeBase: file:///C:/Windows/assembly/GAC_32/System.Data/2.0.0.0__b77a5c561934e089/System.Data.dll

----------------------------------------

Interop.OPCAutomation

    Assembly Version: 1.0.0.0

    Win32 Version: 1.0.0.0

    CodeBase: file:///C:/Users/user/Desktop/IPCForPIERBURGSUV2018/PlantAdminForPIERBURG/bin/Release/Interop.OPCAutomation.DLL

----------------------------------------

 

************** JIT Debugging **************

To enable just-in-time (JIT) debugging, the .config file for this

application or computer (machine.config) must have the

jitDebugging value set in the system.windows.forms section.

The application must also be compiled with debugging

enabled.

 

For example:

 

<configuration>

    <system.windows.forms jitDebugging="true" />

</configuration>

 

When JIT debugging is enabled, any unhandled exception

will be sent to the JIT debugger registered on the computer

rather than be handled by this dialog box.

 

如下图所示,在app.config里配置一行即可。

    <system.windows.forms jitDebugging="true" />

加完这个记录后就正常了。。。。

 

posted @ 2018-08-02 15:28  小半个程序猿  阅读(1285)  评论(0编辑  收藏  举报